Super Hot Allied Engineering Company - Manufacturer of Hydronic & Domestic Water Heating Equipment
 

Mini-Star Electric Series

 
 
Literature
 

 
 Brochure 

 Dimensions & Specifications

 BC-1 Controller Manual 

 Installation & Service Manual 

 
 
Design Features
 
 
Advanced BC-1 Microcontroller
  with Outdoor Reset customizes to any application
Pre-wired and clearly labeled
  Terminal Blocks for quick wiring setup
Quiet and Reliable Contactors
Wall hung
Compact and Lightweight for an
  easy install
Every boiler pressure tested for
  Quality Assurance
Designed to ASME Code
  Section IV for a maximum pressure of 90 psi.
10 year limited warranty on tank,
  1 year on component parts. See warranty for details.

 
 
Special Features
 
 
Powered Contacts for 24 Volt
  Alarm and 120 Volt Pump
Flow Switch Terminals
Flange Elements
Dual High Limit Shut Down
50 VA Transformer
Failed Contactor Safety
  Circuit offers back up protection to shut down a “runaway” boiler even if a contactor fails
Factory Wired for Quick Install
  and Easy Access to the control panel for service

Comfort • Safety • Dependability
With the New BC-1 Microcontroller,
100% Fuel Efficiency and Greenhouse
Gas (GHG) Emission-free Performance.

Hydronic Heating Applications
Residential to Commercial
6 to 54 kW
Single Phase: 208 or 240 Volts
Three Phase: 208, 240, 480 or 600 Volts

The mini-star Electric Boiler offers exceptional comfort and performance in a complete range of sizes to handle any of your hydronic heating needs. Using clean and convenient electric heat, the mini-star achieves a fuel utilization efficiency even greater than that of a condensing boiler while at the same time saving the need to install gas supply piping and venting. It is the perfect solution to escalating gas prices.

IDEAL FOR:

  Residential or Commercial Heating
  New installation or replacement
  Heat source for Radiant Floor, Baseboards, Radiators, Water Coils, etc.
  Supplemental heat for Geothermal or Solar heating systems.
  Back-up heat supply
  Domestic hot water (DHW) heating when used with an Indirect Water Heater

BC-1 MICROCONTROLLER

 
3 stage phased in power draw reduces surges and automatically adjusts heat output to
   
match heating load
 
PID logic (proportional, integral, derivative) – controller determines optimum time delays
   
and inter-stage differentials to eliminate temperature swings, optimize cycle time, and reduce component wear
 
Six Modes of Operation, including Domestic Hot Water (DHW) Generation when used
   
with an Indirect Hot Water Tank
 
Outdoor Reset – user-programmable Reset Curve automatically adjusts for seasonal
   
changes in Heat Load
 
Warm Weather Shut Down (WWSD) for outdoor reset applications shuts off boiler during
   
periods of warmer weather.
 
LCD screen displays:
   
  Temperature of Boiler Outlet, Boiler Inlet, Outdoor and DHW/Secondary Loop
  Call-for-heat, DHW Demand, Pump and Heating stages
  Recorded Boiler running time
  Sensor and Controller Error Messages
 
Exercising of Pump during periods of no operation
 
Built-in test routine for checking control outputs

 
 